Sand gold deposit mining method

It is divided into open air and underground mining.

First, open-pit mining:

(1) Full mining:

Including the layer containing ore to the upper limit surface to the object can be regarded as containing gold mining site for the lower limit of all loose deposits, known as mixed sand. At present, comprehensive mining is mainly carried out by gold mining and water gun mining.

1. Mining of gold mining vessels: Gold mining vessels are mining and selecting combined mechanical equipment floating on the water. It is one of the most advanced methods for mining gold gold. It is suitable for mining floodplains and shores with low grade and large reserves. Shore sand gold mine. The mining technical conditions for gold mining vessels are shown in Appendix 1.

2. Water gun mining: The high-pressure water jet sprayed by the water gun is used to flush the mining sand, and then transported to the beneficiation system with a sand pump. The minimum width of the mining face is 20 meters. The minimum ore content is between 5 and 1.5 million cubic meters, and the water consumption per cubic meter of ore is generally 15 to 22 cubic meters. The water gun mining is suitable for the slope of the ore body floor, the debris material is easy to be washed, and the section height of the stope is not more than 20 meters, or the gold deposit in the terrace.

(2) Mining separately:

The mining sand layer is opened after the mud layer is peeled off. It is suitable for mining deposits with clear boundaries of sand and ore layers and suitable for stripping mining.

Second, underground mining:

It is suitable for mining deposits with high grade and deep burial deposits that are not suitable for open pit mining. The height of the mining frame is 1.3 to 1.5 meters from the surface of the bedrock. If the thickness of the ore layer is less than the height of the mining frame, it can be measured by the value of the meter.

Holter ECG Monitoring System

Introduction

Holter ECG Monitoring Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.


Analysis Software Function

1.The rate of checking RR wave up to 99.9%, which increased the accuracy of analysis without losing wave.

2.AI histogram function which can directly distinguish various abnormal ECG which can analyze faster.

3. Dynamic ECG [Channel Correct" function, which can correct mistakenly wearing that makes the analysis more accurate.

4.Lorenz and Demix analysis function, which can analyze more faster, more accurately. Single medical case can be completely analyzed in 10 min, which can reduce the physician`s work.

5.ST can be displayed in many kinds of form, which ensures that analyzing ST- Trends Diagram comprehensively, observing the whole or partial ST variety to analyze the specific area of myocardial ischemia.

6.Atrial fibrillation function can be recognized automatically and can distinguish atrial fibrillation case, give advice and generate analysis report .

7.Unique Cardiac Fatigue Index function, which can judge index of Cardiac Fatigue .High-risk groups can be found and early intervention treatment can be taken by the index, which can effectively judge the heart age and predict SCD (Sudden Cardiac Death).

8. P-wave analysis function, which can check cardiac arrhythmia (such as AVB).

9.According to the requirement of patients, options can be selected freely while printing report, which can save physician `s time

10. ECG can be printed by various forms according to the user`s requirement.

11.Pacemaker analysis function, which can analyze different pacemakers(such as AAI,VVI,DDD).

12.The comprehensive analysis system of stand-alone version with network version ,users can freely select any model.

13.Wire and wireless simultaneously transfer mode ,which reduce complicated performance.

14. Dynamic ECG and static ECG analysis system ,which reduced complex operations.

15. Time Domain and Frequency Domain function on HRV module can reflect the moderation effect of sympathetic and parasympathetic to the heart rate.

16.HRT function can predict myocardial infarction which has clinical value.

17.ST function which can check the exact time and length of myocardial ischemia in 24 hours.



Holter Monitor,Holter 24 Hours,Holter Recorder,Holter Ecg Monitoring System

Changchun Yingwang Times Digital Co., Ltd. , https://www.ccsdsm.com